Item | Unit | data | Remarks |
Electric furnace parameters | |||
Rated capacity | T | 5 | Liquid iron |
Maximum capacity | T | 7 | Liquid iron |
Maximum working temperature | ºC | 1850 | |
Lining thickness | mm | 120 | |
Induction ring internal diameter | Mm | 1160 | |
Height of Induction ring | Mm | 1880 | |
Electrical parameters | |||
Transformer capacity | KVA | 4000 | |
Primary voltage of transformer | KV | 35KV | |
Transformer second voltage | V | 660 | 12 pulse double output |
Rated Power of medium frequency | KW | 3000 | 12 pulse double input |
Rated input current | A | 3300 | |
DC voltage | V | 890 | |
DC current | A | 2250 | |
Transformation efficiency | % | 96 | |
Startup success rate | % | 100 | |
Maximum output voltage of medium frequency power supply | V | 2000 | |
Rated working frequency | Hz | 500 | |
Power conversion efficiency | % | 96 | |
Working noise | DB | ≤75 | |
Comprehensive parameters | |||
Melting rate (heating up to 1600ºC | T/h | 5.50 | The time used to melt a furnace is related to the feeding |
Melting electricity consumption (heating up to 1600 ºC) | KW.h/T | 620 | |
Hydraulic system | |||
Capacity of hydraulic station | L | 600 | |
Working pressure | MPa | 11 | |
Hydraulic medium | Hydraulic oil | ||
cooling water system | |||
Cooling water flow | T/h | 100 | |
Water supply pressure | Mpa | 0.25-0.35 | |
Water inlet temperature | C | 5-35 | |
Water temperature | C | <55 |