Customization: | Available |
---|---|
Certification: | CE, ISO |
Place Style: | Horizontal |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Project | Unit | Data | Remarks |
Electric furnace parameters | |||
Rated capacity | t | 2 | liquid steel |
Maximum capacity | t | 2 | liquid steel |
Maximum working temperature | ºC | 1650 | |
Thickness of furnace lining | mm | 120 | |
Inner diameter of the induction coil, with a diameter | mm | 840 | |
Induction coil height | mm | 1350 | |
Electrical parameters | |||
Transformer capacity | KVA | 12 pulse dual rectification | with a 2t smelting furnace |
Transformer primary voltage | KV | 10KV | |
Transformer secondary voltage | V | 575 | 12 pulse dual output |
Rated power of intermediate frequency power supply | KW | 1250 | 12 pulse dual input |
Rated input current | A | 1500 | |
DC voltage | V | 780 | |
DC current | V | 1900 | |
Transformation efficiency | % | 96 | |
Start success rate | % | 100 | |
The maximum output voltage of the intermediate frequency power supply | V | 2300 | |
Rated operating frequency | HZ | 500 | |
Power conversion efficiency | % | 96 | |
Working noise | db | ≤ 75 | |
Comprehensive parameters | |||
Melting rate (heating up to 1450 ºC) | T/h | 2.6 | The time required to melt one furnace is related to the addition of materials |
Melting power consumption (heated to 1450 ºC) | kW. h/T | 550KW. h/t ± 5% | |
hydraulic system | |||
Work flow rate | L/min | 9-12 | |
Hydraulic medium | hydraulic oil or flame retardant oil | ||
cooling water system | |||
Cooling water flow rate | T/h 50 | medium frequency power supply and furnace body | |
Water supply pressure | Mpa | 0.25-0.35 | |
Inlet water temperature | ºC | 5-35 | |
Water outlet temperature | ºC | <55 |