Environment
a. The altitude does not exceed 1000m.
b.The ambient temperature is between 5 ºC and 40 ºC.
c. The relative humidity shall not exceed 90% (at 25 ºC).
d. There are no conductive dust, explosive gases, or corrosive gases that can damage metals and insulation around.
e. There are no obvious vibrations or bumps. Power supply requirements
a.The main circuit supply voltage is 1OKV, with a fluctuation of no more than 5%, and the three-phase imbalance is no more than 5%.
b. The power supply voltage of the control system is 220V, with a fluctuation of no more than 5%.
c. The power supply voltage of the main circuit and control system must be a sine wave, with waveform distortion not exceeding 10%. Requirements for external circulation cooling water
a. Total hardness<60mg equivalent/L
b. Dissolved solids<300mg/L
c. PH value 7-8.5
d. Suspended solids<10mg/L
e. Conductivity<500 μ S/cm
f. Inlet water temperature ≤ 35 ºC Electrical technical description
The electrical part of the equipment includes power rectifier transformers, intermediate frequency power control cabinets, compensation capacitor banks, water cooling systems, etc. Power transformer (provided by the user)
The power rectifier transformer is used to reduce the 1OKV high voltage of the power grid to a voltage suitable for intermediate frequency power supply. This equipment adopts a 12 pulse rectifier transformer specifically designed for smelting, which is oil immersed and self cooled. The rated capacity of the transformer is 2200KVA, with a primary voltage of 1KV and a secondary voltage of 660V; Two sets of winding outputs, star and delta, with a short-circuit impedance between 6% and 8%. On the high-voltage side of the transformer, there is an unloaded manual voltage regulating switch that can be adjusted in three levels:-5%, 0%, and+5%.
2200KVA12- rectifier transformer More details contact us pls . we'd like provide more for you ,hope we have chance to cooperate with you.